hazard-tree-identification-graphic.pngSome common tree deficiencies which contribute to potential felling hazards:

Weak Limbs: limbs of all sizes and species with decay evident cracking, loose, hung-up, or fire damaged limbs. Avoid working under overhead hazards.

Weak Tops: split/schoolmarm tops that could have weakened unions, fire weakened tops, rotten or dead tops.

Witches Broom: caused by mistletoe infection, limbs can grow very large and heavy (200+ lbs). Can contribute to uneven weight distribution.

Split Trunk: cracked trunk from frost, lightning, or wind. Visible evidence of advanced decay indicates serious weakness where the tree could fail. May increase wood fiber tension contributing to barber chair potential.

Stem Damage: caused by windfall, scarring, fire, machine, and animal damage, as well as heart rot diseases.

Cat Face:  look for enough solid wood to construct an effective undercut and back cut. Complexity increases when desired felling direction is different than that of the cat face.

Thick Sloughing Bark: usually found on dead trees. Loose bark, particularly on Douglas firs, can injure sawyers.

Butt and Stem Cankers: usually found on deciduous trees but can occur on Douglas fir and pine. The infected areas weaken the stem.

Fungal Fruiting Bodies or Conks: found on stems may indicate massive interior rot. Excessive resinosis (resin flow) also indicates heart or root diseases.

Heavy Tree Lean: look for any ground cracks around the base of the tree. May be caused by damaged roots or lifting root mats, shallow or wet soils. In some cases, the tree may have corrected itself which can be determined by looking for corrected top growth.

Root Condition: weakened roots may reduce felling control. Signs of decay or fungal conks on the roots, or fire weakened roots.

Species Consideration: consult local experts for species deficiencies particular to local areas. A good habit is to observe overall tree stand health wherever you’re working.

Felling a hazard tree requires accurate risk assessment and complexity analysis and demands the sawyer’s full situational awareness. Do not bypass hazard trees without taking some action such as felling or establishing a No-Work-Zone.

Discuss indicators of tree defects specific to your local area.

 

Category

Last Modified / Reviewed:


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

NWCG Latest Announcements

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508

WFSTAR 2025 Core Component Module Package and 2024 Fire Year in Review Now Available

Date: March 14, 2025
Questions?  Please contact:
Joe Schindel at mschindel@blm.gov
 

The 2025 Core Component Module Package for RT-130, Wildland Fire Safety Training Annual Refresher (WFSTAR) and the 2024 Fire Year in Review are now available on the NWCG website. The 2025 Core Component Module Package provides all content needed to deliver RT-130.

References:

2025 Core Component Module Package

2024 Fire Year in Review Module

NEW! NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053

Date: March 12, 2025
Contact: Wildland Urban Interface Mitigation Committee

The NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 provides mitigation practitioners at all experience levels with recommendations on the most effective and efficient ways to accomplish mitigation work in communities at risk to wildfire damage or destruction. The content in this guide was written in coordination with the NWCG Standards for Mitigation in the Wildland Urban Interface, PMS 052.

References:

NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 

Updated, NWCG Standards for Wildland Fire Module Operations, PMS 430

Date: March 11, 2025
Contact: Fire Use Subcommittee
Wildland Fire Module Unit

The NWCG Standards for Wildland Fire Module Operations, PMS 430 standardizes procedures and expectations for Wildland Fire Modules (WFMs). These standards are to be used by staff, supervisors, specialists, and technicians for planning, administering, and conducting WFM operations. These standards will also be used as a measure of WFM qualifications, capabilities, and expected performance, for both Type 1 and Type 2 WFMs.

References:

NWCG Standards for Wildland Fire Module Operations, PMS 430