Skip to main content

Lookouts (LCES)

 

Lookouts provide time-sensitive information to firefighters. This Standard Firefighting Order demonstrates firefighters installing a pump and hose lay with a designated lookout to keep watch for and communicate possible hazards.

5. Post lookouts when there is possible danger. A firefighter works by a water pump in a creek.  Two firefighters spray water onto flames.  And another firefighter talks into a radio while observing all firefighters.

5. Post lookouts when there is possible danger.
 

Read about all 10 Standard Firefighting Orders.

Lookouts are often best situated to notice the cumulative changes of fire behavior.

Standard Firefighting Order #5 is: Post lookouts when there is possible danger.

  • Discuss why lookouts should be posted at all times.

What are you looking for when you are selecting a lookout location?

  • Choose a good vantage point, preferably with a good overview of the entire area where firefighters are located, including escape routes and safety zones.
  • Never rely exclusively on aircraft as your lookout.

What are the desired qualities, capabilities, knowledge, and responsibilities of a lookout?

  • Experienced firefighter.
  • Solid knowledge of fire behavior and the ability to recognize and monitor other environmental hazards.
  • Knowledge of crew locations, escape and safety locations, and trigger points.
  • Good communicator.
  • Knowledge of weather patterns, and signs of incoming weather changes.
  • Advises the crew of fire behavior changes, and tracks weather trends and relays the information.
  • Monitors and accounts for all individuals within the assigned area at all times, and notifies others if breaks are needed.

What is the necessary equipment for a lookout?

  • Personal protective equipment (PPE), radio with extra batteries, compass, binoculars, belt weather kit, an Incident Action Plan (IAP), map, food, water, and watch.

 

6MFS Suggestion Form


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

Last Modified / Reviewed:

NWCG Latest Announcements

ETC Equipment Bulletin: 25-003 Flame-Resistant Shirt Survey

Date: June 12, 2025
Questions?  Please contact:
Equipment Technology Committee

The U.S. Forest Service National Technology and Development Program (NTDP) is seeking input on the Forest Service-designed flame-resistant (FR) shirt, currently available through the National Interagency Support Cache system and FedMall.

NTDP is conducting a product review to improve future FR shirt designs. As part of this effort, a short survey is now open for federal employees who have worn any of three recent FR shirt models. Feedback will guide design improvements to better meet the needs of wildland firefighters.

To comply with the Paperwork Reduction Act, responses are limited to federal employees. The survey is open through September 12, 2025. 

References:

NWCG Alerts

ETC Equipment Bulletin: 25-003

NEW! S-130, Firefighter Training (Blended) Now Available

Date: June 10, 2025
If you have questions, please visit our FAQ page. 
If your question is not answered there, you can 
submit your question using our Contact Us form. 
 

The S-130, Firefighter Training (Blended), equips new wildland firefighters with essential skills through a mix of online learning and hands-on training. The course features a required online component and an instructor-led exercise, reinforcing online concepts with practical performance-based training.

The course builds competencies in wildland fire operations, safety, and equipment use, applicable across various operational environments. Both the online component and instructor-led field exercise must be completed to receive a certificate of completion. Students are required to finish the prerequisite S-190, Introduction to Wildland Fire Behavior, before enrolling in S-130, Firefighter Training (Blended).

References:

S-130, Firefighter Training (Blended)

S-190, Introduction to Wildland Fire Behavior

Wildland Fire Learning Portal

EMC Memo 25-001: Interim Rapid Extraction Module (REMS) Training and Qualification Requirements

Date: June 3, 2025
Questions?  Please contact:
Emergency Medical Committee

The Emergency Medical Committee has issued interim guidance for Rapid Extraction Module Support (REMS) teams. Until further notice, Type I and II REMS teams must designate a team leader qualified at Firefighter Type 1 Squad Boss (FFT1) or higher. This temporary change replaces the Single Resource Boss (SRB) requirement, which is currently not feasible due to administrative barriers.

This memorandum does not include any other changes to the NWCG Standards for Rapid Extraction Module Support, PMS 552. This interim change takes effect immediately and will remain in place until further notice.

References:

EMC Memo 25-001: Interim Rapid Extraction Module (REMS) Training and Qualification Requirements

NWCG Standards for Rapid Extraction Module Support, PMS 552

Equipment Bulletin 25-002: Chaps, Chain Saw, M-2020, Nonconformities Affecting Use, Appearance, and Serviceability

Date: June 2, 2025
Questions?  Please contact:
Equipment Technology Committee

The Equipment Technology Committee issued Equipment Bulletin: 25-002 to address a manufacturing nonconformity affecting Forest Service specification, 6170-4K Chain Saw Chaps. The issue applies to chaps manufactured in 2024 and 2025 and distributed through FedMall. These chaps may have incorrectly bound edges that expose inner protective layers.

Independent purchasers should inspect all chain saw chaps received from FedMall beginning in 2024, prior to use. Review the full Equipment Bulletin: 25-002 for inspection criteria and recommended actions.

References:

NWCG Alerts

ETC Equipment Bulletin: 25-002