Skip to main content

Safety Zone Research

 

Please watch the video for this subject.

Time 6:15

 

First, a Fire Behavior 101 refresher:  You can warm yourself around the sides of a campfire for quite some time; that’s radiant heat. If you hold your hands over the top of the fire, you’ll get burned relatively quickly; that’s convective heat.

Basically, wind or slope can tip the flames over, so that the convective heat is no longer going straight up, but is now aimed more along the ground, sending the heat and hot gasses much further ahead. This causes preheating of the fuels, faster fire spread, and greater fire intensities. You’ll need a larger safety zone if that fire is coming towards you.

The current equation for safety zone size on the Safety Zones page of the Incident Response Pocket Guide (IRPG), PMS 461:

4 x Flame Height = Safe Separation Distance

To make estimations of flame height though, you either have to use past fire behavior observations or use your experience to guess what the fire may do in the future. After a decade of research, Bret Butler, at the Missoula Technology and Development Center, suggests removing the uncertainty and guesswork that comes with estimating flame height by taking the general rule of thumb:

Flame Height = 2 x Vegetation Height

…and substituting that Flame Height equation into the original IRPG equation, to give:

4 x 2 x Vegetation Height = Safe Separation Distance, which simplified is:
 8 x Vegetation Height = Safe Separation Distance

But remember, that’s still for radiant heat only, on flat ground, with no wind. To take into account the convective heat from slope or wind, Butler’s research suggests that a Slope Wind Factor is needed in the equation:

8 x Vegetation Height x Slope Wind Factor = Safe Separation Distance

But what is the Slope Wind Factor? Current research is indicating that the Slope Wind Factor is between 1 and 10, with Butler arguing it may be closer to between 1 and 5. Butler’s ongoing research is focused on answering that question by gathering sensor data on fires, running computer simulations, and refining the models.

In the meantime, utilize the calculations in the Safety Zones page of your IRPG to help you determine a bare minimum size for your safety zone with the understanding that slope and wind need to be considered in your decision-making.

But remember, a safety zone is only good if you can get there.

 

6MFS Suggestion Form


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

Last Modified / Reviewed:

NWCG Latest Announcements

EMC Memo 25-001: Interim Rapid Extraction Module (REMS) Training and Qualification Requirements

Date: June 3, 2025
Questions?  Please contact:
Emergency Medical Committee

The Emergency Medical Committee has issued interim guidance for Rapid Extraction Module Support (REMS) teams. Until further notice, Type I and II REMS teams must designate a team leader qualified at Firefighter Type 1 Squad Boss (FFT1) or higher. This temporary change replaces the Single Resource Boss (SRB) requirement, which is currently not feasible due to administrative barriers.

This memorandum does not include any other changes to the NWCG Standards for Rapid Extraction Module Support, PMS 552. This interim change takes effect immediately and will remain in place until further notice.

References:

EMC Memo 25-001: Interim Rapid Extraction Module (REMS) Training and Qualification Requirements

NWCG Standards for Rapid Extraction Module Support, PMS 552

Equipment Bulletin 25-002: Chaps, Chain Saw, M-2020, Nonconformities Affecting Use, Appearance, and Serviceability

Date: June 2, 2025
Questions?  Please contact:
Equipment Technology Committee

The Equipment Technology Committee issued Equipment Bulletin: 25-002 to address a manufacturing nonconformity affecting Forest Service specification, 6170-4K Chain Saw Chaps. The issue applies to chaps manufactured in 2024 and 2025 and distributed through FedMall. These chaps may have incorrectly bound edges that expose inner protective layers.

Independent purchasers should inspect all chain saw chaps received from FedMall beginning in 2024, prior to use. Review the full Equipment Bulletin: 25-002 for inspection criteria and recommended actions.

References:

NWCG Alerts

ETC Equipment Bulletin: 25-002

2024 Wildland Fire Emergency Medical Service Awards

Date: May 22, 2025
Questions?  Please contact:
Emergency Medical Committee

The NWCG Emergency Medical Committee (EMC) is proud to announce the recipients of the 2024 Wildland Fire Emergency Medical Service Awards. Each year, EMC recognizes individuals and groups who have demonstrated exceptional actions or accomplishments that go above and beyond their normal mission or job duties.

Congratulations to all the awardees and nominees. Through leadership and initiative, they have made significant contributions to the safety and well-being of the wildland fire community. These honors are well deserved.

References:

2024 Wildland Fire EMS Awards

NWCG Emergency Medical Committee

NWCG Welcomes the Incident Management Teams Association as an Associate Member

Date: May 21, 2025
Questions?  Please contact:
https://www.nwcg.gov/contact-us

The NWCG Executive Board is honored to announce that the Incident Management Teams Association (IMTA) has joined the National Wildfire Coordinating Group as an associate member.

IMTA is a dedicated group of incident management professionals committed to enhancing the profession by promoting standards and fostering collaboration across federal, state, local, Tribal, and private sector partners throughout all phases of incident management.

“Joining NWCG aligns with our mission to elevate incident management professionals nationwide,” said Dr. Randal Collins, President of IMTA. “This is a proud moment for all of us committed to advancing public safety.”

References:

Incident Management Teams Association

National Wildfire Coordinating Group