Skip to main content

Wildland Urban Interface – Structure Protection

 

The primary consideration of any operation is to assure firefighter and public safety. It is a must to assess potential fire behavior, ingress/egress routes, nature of the threat, hazardous materials, and available water supplies before engaging in the protection of any structure.

Factors that may make an attempt to save a structure too dangerous include:

  • The fire is making a sustained run and there is little or no clearance between the structure and the fuel.
  • The fire behavior is extreme; spot fires are numerous and the spread is outpacing containment.
  • Water supply will not last as long as the threat of the fire.
  • The fire intensity dictates that you leave the fire area immediately.
  • The structure is constructed of wood and has a wood shake roof.
  • The roof of the structure is more than one-quarter involved.
  • There is fire inside of the structure, or windows are broken and there is no way to quickly repair them.
  • You cannot safely remain at the structure because your escape route could become unusable.

When implementing a plan to protect structures, consider the following:

  • Do not enter a burning structure unless you are trained, equipped, and authorized. Firefighter safety and survival is the number one priority.
  • Always stay mobile and wear all personal protective equipment (PPE).
  • Back in equipment to allow for a quick escape.
  • Coil a short, charged line with a fog nozzle on your engine for safety and quick knockdown capability.
  • Don’t make long hose lays.
  • Reserve at least 100 gallons of water in your tank.
  • Check the road system before the fire approaches. Know bridge limits, alternate access routes, and turnarounds for your vehicle and other support vehicles.
  • Determine if residents are home. Leave the inside and outside lights on, regardless of the time of day. Close the garage door.
  • Place the owners’ ladder at a corner of the home on the side with the least fire threat.
  • Coil and charge garden hoses.
  • Check and mark hazardous materials (e.g., Liquefied Propane Gas [LPG] tanks, pesticides, and paint storage.

 

6MFS Suggestion Form


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

Last Modified / Reviewed:

NWCG Latest Announcements

EMC Memo 25-001: Interim Rapid Extraction Module (REMS) Training and Qualification Requirements

Date: June 3, 2025
Questions?  Please contact:
Emergency Medical Committee

The Emergency Medical Committee has issued interim guidance for Rapid Extraction Module Support (REMS) teams. Until further notice, Type I and II REMS teams must designate a team leader qualified at Firefighter Type 1 Squad Boss (FFT1) or higher. This temporary change replaces the Single Resource Boss (SRB) requirement, which is currently not feasible due to administrative barriers.

This memorandum does not include any other changes to the NWCG Standards for Rapid Extraction Module Support, PMS 552. This interim change takes effect immediately and will remain in place until further notice.

References:

EMC Memo 25-001: Interim Rapid Extraction Module (REMS) Training and Qualification Requirements

NWCG Standards for Rapid Extraction Module Support, PMS 552

Equipment Bulletin 25-002: Chaps, Chain Saw, M-2020, Nonconformities Affecting Use, Appearance, and Serviceability

Date: June 2, 2025
Questions?  Please contact:
Equipment Technology Committee

The Equipment Technology Committee issued Equipment Bulletin: 25-002 to address a manufacturing nonconformity affecting Forest Service specification, 6170-4K Chain Saw Chaps. The issue applies to chaps manufactured in 2024 and 2025 and distributed through FedMall. These chaps may have incorrectly bound edges that expose inner protective layers.

Independent purchasers should inspect all chain saw chaps received from FedMall beginning in 2024, prior to use. Review the full Equipment Bulletin: 25-002 for inspection criteria and recommended actions.

References:

NWCG Alerts

ETC Equipment Bulletin: 25-002

2024 Wildland Fire Emergency Medical Service Awards

Date: May 22, 2025
Questions?  Please contact:
Emergency Medical Committee

The NWCG Emergency Medical Committee (EMC) is proud to announce the recipients of the 2024 Wildland Fire Emergency Medical Service Awards. Each year, EMC recognizes individuals and groups who have demonstrated exceptional actions or accomplishments that go above and beyond their normal mission or job duties.

Congratulations to all the awardees and nominees. Through leadership and initiative, they have made significant contributions to the safety and well-being of the wildland fire community. These honors are well deserved.

References:

2024 Wildland Fire EMS Awards

NWCG Emergency Medical Committee

NWCG Welcomes the Incident Management Teams Association as an Associate Member

Date: May 21, 2025
Questions?  Please contact:
https://www.nwcg.gov/contact-us

The NWCG Executive Board is honored to announce that the Incident Management Teams Association (IMTA) has joined the National Wildfire Coordinating Group as an associate member.

IMTA is a dedicated group of incident management professionals committed to enhancing the profession by promoting standards and fostering collaboration across federal, state, local, Tribal, and private sector partners throughout all phases of incident management.

“Joining NWCG aligns with our mission to elevate incident management professionals nationwide,” said Dr. Randal Collins, President of IMTA. “This is a proud moment for all of us committed to advancing public safety.”

References:

Incident Management Teams Association

National Wildfire Coordinating Group