Skip to main content

Proper Use of Trigger Points

 

The 10 Standard Firefighting Orders and the 18 Watch Out Situations, as referenced in the Incident Response Pocket Guide (IRPG), PMS 461, provide wildland firefighters with a set of consistent best practices and a series of scenarios to be mindful of when responding to a wildland fire.

Accurate situation awareness (SA) requires a constant reassessment of conditions (existing and potential) that may impact the safety and effectiveness of tactics. Monitor for the 18 Watch Out Situations and establish trigger points (in the form of operational or environmental limits) ahead of time.

Remember, trigger points are not decision-makers but serve as predetermined cues to prompt you to re-evaluate the current and potential situation and its associated risks. They help you to determine and implement the proper course of action.

The following items are considerations in your planning and discussion.

  • Use trigger points for preplanning. Do not wait until you are in the wrong place at the wrong time – with no time.
  • Trigger points should be based on measurable factors such as: ​
    • Relative Humidity (RH).
    • Winds.
    • Fire behavior.
    • Topographical boundaries.
    • Time constraints/time of day.
    • Time/distance to safety zones.
    • Loss of suppression resources.
    • Other operational considerations (e.g., firefighter fatigue, loss of lookouts or communication, weather change).
  • As you approach predetermined trigger points, go through the Risk Management Process to help you decide if a change in tactics is required:
    • Identify hazards.
    • Assess hazards.
    • Develop controls and make risk decisions.
    • Implement controls.
    • Supervise and evaluate. ​
  • Consider the following command/leadership responsibilities when changing tactics:
    • Communicate the changes to your subordinates, as well as to adjacent forces and up the chain of command.
    • Account for all your people.
    • Make sure everyone knows and follows the new plan. ​

 

 

Last Modified / Reviewed:


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

NWCG Latest Announcements

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1

NWCG NFES Catalog-Part 2: Publications, PMS 449-2

NEW! Air Operations Summary (ICS 220 WF) Now Available

Date: May 2, 2025
Questions?  Please contact:
National Interagency Aviation Committee

The Air Operations Summary (ICS 220 WF) provides the Air Operations Branch with the number, type, location, and specific assignments of helicopters and air resources. The new ICS 220 WF also includes medical extraction capabilities and air resources tracking.

Understanding the capabilities of aviation assets is critical for effective medical and extraction responses. Coordination with the Medical Unit Leader is essential to ensure alignment and consistency between the ICS 220 WF and the Medical Plan (ICS 206 WF). 

References:

Air Operations Summary (ICS 220 WF)

National Interagency Aviation Committee

Incident Command System (ICS) Forms