Skip to main content

Firefighter Type 1 (Squad Boss)

Position Description

Duties

  • Briefs subordinates on tactical assignment, fuels, topography, weather, safety zones and escape routes throughout the operational period.
  • Responsible for the safety and welfare of subordinates during assignments, especially when separated from the balance of the crew.
  • Develops instantaneous tactics as required by the fuel type, weather, terrain conditions, in conjunction with defined strategy received from supervisor.
  • Properly uses portable or mobile multi-channel radio.
    • Uses correct nomenclature.
    • Correctly prepares radio for operation.
    • Successfully completes radio check.
    • Selects proper channel.
    • Makes appropriate adjustments (squelch/volume).
    • Changes location to improve reception/transmission (as needed).
    • Protects radio from damage at all times.
    • Uses proper radio procedures and techniques.
    • Exercises proper radio discipline.
    • Describes agency procedures for emergency notification (emergency traffic).
    • Describes limitations of radio communications.
  • Properly uses maps and compass.
    • Accurately determines local declination.
    • Uses compass to point to true north.
    • Accurately orients map using compass, landmarks, improved properties, streets, access roads, and topographic features.
    • Accurately identifies current location by determining back azimuths to two identifiable landmarks or topographic features.
    • Verifies location by comparing topographic features or street references with map.
    • Describes location in terms of coordinates or other acceptable description.
    • Accurately reads map symbols.
    • Accurately computes distance and bearing.
    • Navigates from point to point using map, compass, and pacing.
    • Accurately navigates to an assigned destination.
    • Utilizes available property improvement maps to identify areas of concern.
  • Takes appropriate action to safely initiate action during initial attack or when completing assigned wildland fire or prescribed fire tasks.
    • Evaluates Initial Attack Plan.
    • Directs tactical operations which provide safety to the firefighter.
    • Uses appropriate fire suppression strategy.
    • Develops appropriate tactics based on selected strategy, values to be protected and expected fire behavior.
    • Maintains status reporting (ICS 201, Incident Briefing).
    • Properly locates fireline.
    • Uses appropriate fireline construction methods.
    • Requests additional resources as needed.
    • Directs the rearrangement and reduction of fuel.
    • Directs the securing of hazards.
    • Directs the preparation of building/structure.
    • Direct the application of pre-treatment agents (foam, gel, blanket).
  • Serves as lookout.
    • Establishes/maintains communications with assigned resources.
    • Chooses position with good view of all aspects of hazard, values to be protected, and personnel.
    • Carries proper equipment (watch, map,radio/batteries).
    • Provide updates on any changes that may compromise the safety of fireline personnel.
    • Provides appropriate warnings and direction for hazardous conditions and/or indications of extreme fire behavior.
  • Demonstrates understanding of how to apply the Risk Management Process found in PMS 461, Incident Response Pocket Guide and PMS 410-1, Fireline Handbook.
    • Step 1 Situational awareness
    • Step 2 Hazard assessment
    • Step 3 Hazard control
    • Step 4 Decision point
    • Step 5 Evaluate
  • Checks in at incident.
  • Receives briefing from supervisor.
  • Properly sizes up fire.
  • Demonstrates ability to develop strategy and apply appropriate tactics.
  • Demonstrates ability to reduce threat of fire exposure to improved properties.
  • Demonstrates how to apply LCES.
  • Briefs subordinates or relief.
  • Keeps crewmembers informed on a regular basis about pertinent information.
  • Inspects squad personnel for Personal Protective Equipment (PPE).
  • Inspects assigned equipment and supplies.
  • Provides leadership and supervision for squad members.
  • Assists with preparation of reports and records.
  • Confirms demobilization instructions with supervisor and brief subordinates.

Position Needs

  • S-131, Advanced Firefighting Training
  • Qualified Firefighter Type 2

NWCG Latest Announcements

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505

New Job Aids Available: Packing Lists for Wildland Fire Fireline Personnel and Support Staff, J-101 and J-102

Date: December 3, 2024
Contact: NWCG TRAINING

Two new job aids are now available: Packing List for Wildland Fire Fireline Personnel, J-101 and Packing List for Wildland Fire Support Personnel, J-102, should serve as a baseline for items needed on a wildland fire assignment. These lists will help personnel prepare for a 14 to 21-day assignment on the fireline or in a support role.

References:

Job Aid Catalog

NWCG Packing List for Wildland Fire Fireline Personnel, J-101

NWCG Packing List for Wildland Fire Support Staff, J-102

NWCG Equipment Technology Committee Releases Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Date: November 14, 2024
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention. Misaligned toolless fuel caps on Stihl chainsaws have led to recurring fuel spillage, fuel ignition, and burn injuries during wildland fire management operations.

This Safety Warning is intended to highlight the details and recommended procedures for the installation of a Stihl chainsaw toolless fuel cap, as well as how to identify and correct a misaligned, damaged, or broken fuel cap to help prevent fuel spillage.

References:

NWCG Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Advertencia de equipos 24-001: Prevención de derrames de la tapa de combustible sin herramientas de la motosierra Stihl

NWCG Alerts