Skip to main content

Paramedic Fireline

Position Description

The Paramedic Fireline incumbent provides emergency medical care on an active fireline, division or other physically challenging assignment.  This resource may also provide care in the medical unit and/or at other locations as directed by the Incident Commander or representative.

Introduction

The Paramedic Fireline (EMPF) provides advanced emergency medical care for injured and sick persons.  The position has the knowledge associated with, and is expected to be competent in all of the skills of the EMT and AEMT.  A Paramedic completes a more thorough course of education, which in some states requires the completion of an Associate’s degree.  The paramedic has an in-depth understanding of human anatomy, physiology and pathophysiology which allows them to perform more advanced skills and a broader spectrum of medications than either an EMT or AEMT.  These skills carry a greater risk for the patient if improperly or inappropriately performed, are more difficult to attain and maintain competency in, and require significant background knowledge in basic and applied sciences.

While all Paramedics receive essentially the same training, the specific procedures that each individual Paramedic is authorized to perform vary depending on the Paramedic’s scope of practice.  A Paramedic’s scope of practice contains only those procedures for which he or she is educated, certified (by passing an exam), credentialed (medical director grants “permission” to practice), and licensed by a state to perform.  Therefore, the scope of practice of a Paramedic will vary by individual.

The EMPF will be required to work on the fireline or other remote areas of an incident.  The EMPF would be expected to lead, or at a minimum participate in the evacuation of a sick or injured person from this environment.  The EMPF would also be expected to perform these lifesaving skills with the equipment available to them on the fireline, which is significantly less than those EMTPs in the medical unit or typical urban EMS system.  The EMPF may be the only medical provider on scene for an extended period of time in less than ideal conditions.  The EMPF may direct the others on scene in providing care on critically injured or sick patients and will generally have the role of team leader in these situations.

Skills, Knowledge, and Abilities

The following are the minimum psychomotor skills of the Paramedic:

  • Airway and Breathing
    • Perform endotracheal intubation
    • Perform percutaneous (not to include ‘surgical’ access using a scalpel) cricothyrotomy
    • Decompress the pleural space of the chest cavity
    • Perform gastric decompression
    • Monitor and interpret Patient oxygen and carbon dioxide levels
  • Pharmacological interventions include
    • Insert an intraosseous (IO) cannula
    • Enteral and parenteral administration of approved prescription medications
    • Access indwelling catheters and implanted central IV ports for fluid and medication administration
    • Administer medications by intravenous (IV), intraosseous, intramuscular, intranasal, sublingual, and subcutaneous routes
    • Maintain an infusion of blood or blood products
  • Medical/Cardiac Care
    • Perform cardioversion, manual defibrillation, and transcutaneous packing
    • Perform and interpret the results of Electrocardiogram (EKG) including 12-lead
  • Evacuation/Transportation
    • Evacuation of a sick or injured patient using purpose made and improvised litters
    • Appropriate triage of sick or injured patients in order to assist with the formulation of an evacuation plan

Position Knowledge and/or Requirements

  • Current Paramedic license (must be issued by the Paramedic’s home-state EMS licensing authority)
  • Introduction to ICS (I-100)
  • NIMS:  An Introduction (IS-700)
  • Firefighter Training (S-130)
  • Introduction to Wildland Fire (S-190)
  • Annual Fireline Safety Refresher (RT-130)
  • Human Factors in the Wildland Fire Service (L-180)
  • An arduous physical fitness level has been established for this position

Other Training Supporting Development of Knowledge and Skills

  • Intermediate Wildland Fire Behavior (S-290)
  • Basic Air Operations (S-270)
  • Helicopter Crewmember (S-271)
  • Advanced Cardiac Life Support (if not required for state licensure)

 

Last Modified / Reviewed:

NWCG Latest Announcements

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505

New Job Aids Available: Packing Lists for Wildland Fire Fireline Personnel and Support Staff, J-101 and J-102

Date: December 3, 2024
Contact: NWCG TRAINING

Two new job aids are now available: Packing List for Wildland Fire Fireline Personnel, J-101 and Packing List for Wildland Fire Support Personnel, J-102, should serve as a baseline for items needed on a wildland fire assignment. These lists will help personnel prepare for a 14 to 21-day assignment on the fireline or in a support role.

References:

Job Aid Catalog

NWCG Packing List for Wildland Fire Fireline Personnel, J-101

NWCG Packing List for Wildland Fire Support Staff, J-102

NWCG Equipment Technology Committee Releases Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Date: November 14, 2024
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention. Misaligned toolless fuel caps on Stihl chainsaws have led to recurring fuel spillage, fuel ignition, and burn injuries during wildland fire management operations.

This Safety Warning is intended to highlight the details and recommended procedures for the installation of a Stihl chainsaw toolless fuel cap, as well as how to identify and correct a misaligned, damaged, or broken fuel cap to help prevent fuel spillage.

References:

NWCG Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Advertencia de equipos 24-001: Prevención de derrames de la tapa de combustible sin herramientas de la motosierra Stihl

NWCG Alerts