Skip to main content

PMS 448

Tent – Wall, 14’ X 16’, Without Poles

NFES #
000084
Category
Camp
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for mold or mildew, rips and tears. Inspect for missing guy ropes and grommets, replace as needed. Validate that item meets NFES item description.
  2. Return to stock if item is dry, clean and in unused condition.
  3. Refurbish tent if tent damage is repairable and is economically feasible to complete.
  4. Dispose of item if mold or mildew is present, if tent is non-standard or fails initial inspection with damage that is not repairable.

Refurbishing Procedures

A. Cleaning

  • Sweep with stiff brush. Wash with warm water and mild detergent and rinse. If necessary, clean stubborn stains with hot water pressure washer using a stiff bristle brush for scrubbing. Ensure tent is dried completely before storage.

B. Repair

  1. Replace missing or damaged guy ropes (¼” X 8’ manila rope) and ridge lines (¼” X 12’ manila rope) and replace missing or damaged grommets with proper size grommets. Complete tent includes: 14 each – 8ft manila ropes and 2 each – 12ft manila ropes.
  2. Patch small holes, rips and tears following manufacturer’s recommendations.

C. Testing for Performance

  • None 

D. Repackaging

  1. Fold tent with guy ropes in the center of folding. Fold so that tent does not have to be turned over when set up (outside of tent is facing up when folding). Package with: 14 EA of stakes-- NFES# 000825 and 22 EA of pins--NFES# 000538.
  2. Local cache option for carton usage.

 

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505