Skip to main content

PMS 448

Introduction PMS 448

These national standards are applicable at National Support Caches and local units. For items that are not identified for refurbishment in this publication, contact your local servicing cache or technical centers for assistance. As new items are introduced, current items are discontinued, and/or health and safety issues arise, these standards will be revised to provide updated information.

The NWCG Standards for Fire Equipment Storage and Refurbishing, PMS 448, are developed and maintained NFES Subcommittee (NFESS) under the direction of the Equipment and Technology Committee (ETC), an entity of the NWCG.
While they may contain relevant or useful information, previsions versions are obsolete. The user of this information is responsible for confirming that they have the most up-to-date version. NWCG is the sole source for the publication.

Comments, questions, and recommendations shall be submitted to the appropriate agency program manager assigned to the NFESS using the NWCG Publication Review Form. View the complete roster.

Prior to refurbishment of any supplies or equipment, refer to your local health and safety reference materials and conduct Job Hazard Analysis (JHA) or risk assessments to identify potential hazards and establish mitigation practices. Reference materials may include USDA Health and Safety Code Handbook, Manufactures’ Safety Data Sheets (MSDS), product owner’s manuals, locally established JHAs, etc.

General guidelines for refurbishment:

  • Inspection: Determine whether or not an item has been used or is in need of refurbishment. This can generally be done by visual inspection for soiling, damage, missing seals, or items being removed from packaging.
  • Refurbishment: Generally this is a three step process consisting of cleaning, repairing and testing of an item before returning to service. Detailed refurbishment instructions are contained in the body of this document.
  • Packaging: Packaging requirements identified are standards established and followed by National Support Caches. Local protocols for packaging may vary from established packaging standards and should be applied as necessary to meet local storage requirements.

Note: Items used for transport, consumption, or storage of potable water or food should be cleaned and sanitized rinsing with mixture of 1 ounce or 1 tablespoon of chlorine bleach thoroughly mixed into a gallon of room-temperature water. Rinse with clean water, drain, and air dry.

For items exposed to the human body, clean and dry using the specific instructions in this document. Examples are Nomex® clothing, neck shrouds, sleeping bags, sleeping pads, and cots. Failure to follow the cleaning instructions may result in the failure of the fabric or materials to correctly or safely perform its function. This procedure also prevents the spread of communicable diseases.

  • Dispose of hazardous materials according to local health and safety regulations.
  • Cache managers or supervisors have the responsibility of determining whether it is economical to refurbish or dispose of an item.
  • Contact your local servicing cache for recycling options and disposal criteria or as local options are available.
  • Users should inspect all items that have been refurbished using some measure for quality assurance.

Abbreviations used:

  • DLT – date last tested
  • GL – gallon
  • LB – pound
  • PSI – pounds per square inch 
  • RPM – revolutions per minute

 

Modified / Reviewed:

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505