Skip to main content

PMS 448

McLeod – 11” Wide w/Plastic Sheath

NFES #
000296
Category
Tools
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for obvious damage to cutting edge, rake fingers, and handle.  Inspect for broken blades, loose heads, missing or severely bent fingers, short or nonstandard handles.
    1. Head
      • Blade to be at least 10 to 14 inches wide from handle base.  USE TEMPLATE.
      • Handle base not tilted, bent, or distorted.
      • Blade ends have not been rounded or severely tapered so that they cannot be ground to specifications.
      • Proper angle of cutting edge as per tool sharpening gauge NFES #000510.
    2. Handle
      • Handle must be straight.
      • Inspect for cracks, chips, or open grain.
      • Head loose on handle (loose or missing rivets).
      • Inspect for tape residue, or other residue (tar, sap, etc.).
  2. Return to stock if item does not show signs of use and passes visual inspection.
  3. Refurbish if damage is detected in the inspection process and is repairable or handle is replaceable
  4. Dispose of item if cutting edge is severely damaged, rake fingers are cracked or missing, or handle base is cracked or damaged.

Refurbishing Procedures

A. Cleaning and Repair

  1. Head
    1. Remove dirt, rust and grime from head with wire brush or hose.
    2. Square up blade if necessary.
    3. Sharpen cutting edge 1/8-inch wide at 50° angle. Ensure that blade corners are square.
    4. Check large nut on head and tighten or replace as needed.   Sharply strike rivet to tighten head to handle as needed.
    5. Apply rust inhibitor to tool head.  Local cache option for painting tool head.    Black paint only.
    6. Replace as necessary.
  2. Handle
    1. Sand handle if it is chipped, dinged, rough or has tape residue. 
    2. Wipe handle with linseed oil after sanding.

B. Test for Performance

  1. Ensure tool is properly sharpened with no deficiency to materials or craftsmanship.
  2. Ensure head and handle are properly attached with no play caused by a loose head or handle.

C. Repackaging

  1. Install plastic sheath NFES #001854.
  2. Package 10 each in NFES #000305 carton (56” x 20” x 11”).

 

NWCG Latest Announcements

Task Group Volunteers Needed to Update the Property Loss or Damage Report, OF 289

Date: February 5, 2025
Contact: Julie Bennett, Incident Business Committee Chair

The Incident Business Committee (IBC) is requesting volunteers for a new task group to revise the 1981 version of the Property Loss or Damage Report, OF 289 and create an incident replacement job aid. The volunteers may be recruited from within or outside the Geographic Area Incident Business Committees.

References:

IBC Memorandum 25-02

IBC Correspondence

2025 Updates to the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1

Date: February 4, 2025
Contact: Incident and Position Standards Committee

The NWCG Incident and Position Standards Committee has updated the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1. 

These updates address changes to incident position names and requirements for qualification, training, and experience. Updates related to the implementation of Complex Incident Management (CIM) are also included.  

The NWCG Wildland Fire Position Qualification Flowchart, PMS 308 has also been updated to reflect the recent changes.

References:

NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1

NWCG Wildland Fire Position Qualification Flowchart, PMS 308

NWCG Memo: 2025-01 January 2025 Updates to the NWCG Standards for Wildland Fire Positions Qualifications, PMS 310-1

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason