Skip to main content

RT-130, Wildland Fire Safety Training Annual Refresher (WFSTAR)

RT-130 Decorative banner. Group of photos depicting wildland firefighters performing various duties.

Felling Hazard Trees: Does it Need to Come Down?

This video promotes dialogue among sawyers and fireline leaders about their ability to discuss and identify expectations and decisions to cut or leave a tree, understand the human factors that influence the decision-making process, and bring awareness to the option that every saw operator has a right to walk away from a tree.
Category: Hazards
Core Component(s):
Local Topics, Incident Reviews and Lessons Learned
Estimated Delivery Time: 45 minutes
Video Length: 13:50

Intent

Create a dialogue among sawyers and fireline leaders about their ability to discuss and identify expectations and decisions to cut or leave a tree. Understand the Human Factors that influence the decision-making process and bring awareness to the option that every saw operator has a right to walk away from a tree.​

Facilitator Preparation

  • Review the video and module tools.
  • Decide which questions will best fit the skill level of the session audience.
  • Consider additional activities and discussion questions pertinent to the location and agency.

Facilitating the Discussion

  • Show the video.
  • Share the intent of the module with the class.
  • Facilitate a small or large group discussion using the selected discussion questions.

Discussion Questions

  1. Define a hazard tree. Is a dead, standing, ember-receptive tree a hazard tree? Do your perceptions of a hazard tree change from hotline construction to mopup? What about from direct line construction to indirect?
  2. What compels us to make the decision to cut the tree in front of us? (Examples include module/crew standard operating procedures [SOPs], personal skills, incident objectives, fireline supervisor, and fireline production rate pressures.)
  3. Which fireline positions make decisions about what trees need to come down? While on fire assignments, do your fireline supervisors (Operations Section Chief, Division Supervisor, Task Force Leader, Strike Team Leader, etc.) provide their tree removal expectations?
  4. Do you have adequate training for the cutting assignment? What influences your decision to walk away/turn down a cutting assignment?  Does your supervisor support you in making these decisions on your own?
  5. What are the key components that must be identified when determining the complexity of a saw operation? How do you determine what level of certification or skill set is needed to safely fell or buck a tree?
  6. If you start cutting a tree and the tree hangs up, what do you do?
  7. Do all hung trees need to be removed?  What influences your decision?
  8. What are the alternatives to cutting down a tree?
  9. Describe a close call you have had with saw work and how it has changed your perception of risk. Looking back, what could have been done to mitigate that close call?
  10. Does your module, team, or crew have SOPs for hazard trees, hung-up trees, alternatives to cutting high complexity trees, and tree turn-down protocols?
  11. Have you seen a change in how the fire service is dealing with tree stand health and hazard trees?
  12. During your fire career, have you heard this statement, “once you put your saw in a tree, it's all yours until it's on the ground.” If so, how do you feel about that statement today?

Feedback

  • Please utilize the PROVIDE FEEDBACK button located at the bottom of the page to provide feedback.
  • The Hazard Tree and Tree Felling Subcommittee is going to create another Hazard Tree module. Please let us know how feel about this video, as well as other issues and topics you would like to see addressed in the future.

Resources

Video Information

  • This video is also available as a download (zip file, size 977 MB) with .srt file for closed captioning (you may need to Right Click and Save As). For information on how to add closed captioning to a video, see this how to page.
  • Note: For Chrome, Firefox, and Edge, right click the word download and select Save Link As; For IE, right click and select Save Target As.

Last Modified / Reviewed:

Please Provide Feedback

NWCG values your constructive input and we thank you for taking the time to provide feedback.

Although contact information is optional, we hope that you provide a way for us to contact you in case we need clarification on your comment. If you would like to be contacted regarding your feedback, you must provide contact information. 

Would you like a response?
If you would like a response, you must provide contact information (name and email) below.
One file only.
9.28 GB limit.
Allowed types: gif, jpg, jpeg, png, bmp, eps, tif, pict, psd, txt, rtf, html, odf, pdf, doc, docx, ppt, pptx, xls, xlsx, xml, avi, mov, mp3, mp4, ogg, wav, bz2, dmg, gz, jar, rar, sit, svg, tar, zip.

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505