Skip to main content

RT-130, Wildland Fire Safety Training Annual Refresher (WFSTAR)

RT-130 Decorative banner. Group of wildland firefighters hiking down a valley to a fire. Black topo map and WFSTAR logo on left.

Counter Rotating Vortex Pairs

This module creates both awareness and conversation among fire personnel around a relatively unknown fire behavior phenomenon called the Counter Rotating Vortex Pair (CRVP). Concisely describe conditions that may lead to CRVP formation for tactical resources like crew lookouts and Division Supervisors (DIVS).
Category: Fire-Environment
Core Component(s):
Fire and Aviation Operational Safety, Human Factors, Communication and Decision Making
Estimated Delivery Time: 35 minutes
Video Length: 09:03

Remote Video

Intent

Create both awareness and conversation among fire personnel around a relatively unknown fire behavior phenomenon called the Counter Rotating Vortex Pair (CRVP). Concisely describe conditions that may lead to CRVP formation for tactical resources like crew lookouts and Division Supervisors (DIVS).

Facilitator Preparation

  • Review the video and module tools.
  • Consider additional activities and discussion questions pertinent to the location and agency.
  • Familiarize with discussion questions and concepts:
  • Consider what a posted lookout could recognize in terms of weather, topography, fire location, and fire behavior that could lead to CRVP formation.
    • Is the fire located on the lee side of a ridge or mountain range?
      • How would a lookout notice wind shear at ridgetop level?
      • What other terrain features that alter general wind flow can you observe?
        • Ridgetops compress airflow, drainages and canyons funnel airflow.
    • Is there a large column from an area ignition or deep flaming zone?
      • A column impedes wind flow and air must flow around it, which can create vorticity (rock in the river analogy).
      • Is the column splitting into two?
      • Are the columns starting to rotate?
  • Given the information in the video, what are other considerations you may think about specific to lookouts in the future?
    • Examples might be physical location, field of view limitations, and/or time of day.
  • Describe ways resources can work together on a fire to interpret and communicate the fire behavior if the conditions for CRVP formation are present.
    • Examples could be strategically, from the Fire Behavior Analyst (FBAN) to DIVS.
    • Or tactically, between crews and their lookouts on a division.
  • Why are Counter Rotating Vortex Pairs dangerous to fireline personnel?
    • Can create locally strong, unpredicted surface winds that exponentially increase spotting potential on the flanks, where firefighters commonly work.
    • Can result in erratic fire behavior and irregular fire spread patterns.

Facilitating the Discussion

  • Show the video.
  • Facilitate a group discussion using the discussion questions.

Questions / Scenario / Directions

  1. Consider what a posted lookout could recognize in terms of weather, topography, fire location, and fire behavior that could lead to Counter Rotating Vortex Pair formation.
    1. Is the fire located on the lee side of a ridge or mountain range?
      1. How would a lookout notice wind shear at ridgetop level?
      2. What other terrain features that alter general wind flow can you observe?
        1. Ridgetops compress airflow, drainages and canyons funnel airflow.
    2. Is there a large column from an area ignition or deep flaming zone?
      1. A column impedes wind flow and air must flow around it, which can create vorticity (rock in the river analogy from video at 6:27).
      2. Is the column splitting into two or does it appear to be “kidney shaped?”
      3. Are the columns starting to rotate?
  2. Given the information in the video, what are other considerations you may think about specific to lookouts in the future? Examples might be physical location, field of view limitations, and/or time of day.
  3. Describe ways resources can work together on a fire to interpret and communicate the fire behavior if the conditions for CRVP formation are present.
    1. Examples could be strategically, from the FBAN to DIVS.
    2. Or tactically, between crews and their lookouts on a division.
  4. Why are Counter Rotating Vortex Pairs dangerous to fireline personnel?
    1. Can create locally strong, unpredicted surface winds that exponentially increase spotting potential on the flanks, where firefighters commonly work.
    2. Can result in erratic fire behavior and irregular fire spread patterns.

Resources

Additional Video Information

  • This video is also available as a download (zip file, size 1.2GB) with the .srt file for closed captioning (you may need to right click and Save As). For information on how to add closed captioning to a video, see this how to page.
  • Note: For Chrome and Firefox, right click the word download and select Save Link As; for IE, right click and select Save Target As.

Please Provide Feedback

Indicates required field

If you would like to provide feedback, NWCG values your constructive input.

Would you like a response?

Although contact information is optional, we hope that you provide a way for us to contact you in case we need clarification on your comment. If you would like to be contacted regarding your feedback, you must provide contact information. 

CAPTCHA
Image CAPTCHA
Enter the characters shown in the image.
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

NWCG Latest Announcements

LMC Equipment Bulletin 26-001: Aquatic Invasive Species – Seasonal Reminder for Mussels

Date:  July 30, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics and Equipment Management Committee (LMC) issued Equipment Bulletin 26-001: Aquatic Invasive Species - Seasonal Reminder for Mussels, reminding the wildland fire community that aquatic mussels continue to be a problem. Mussels rapidly colonize hard and soft surfaces, including aquatic plants and fire equipment, clogging pipes, fouling motors, disrupting water systems, and impacting native species.

To help prevent their spread, fire personnel must follow the decontamination procedures outlined in the NWCG Guide to Preventing Aquatic Invasive Species Transport by Wildland Fire Operations, PMS 444. Additionally, report any sightings immediately to your Lead Resource Advisor and include clear, close-up photos (with a pen or your hand for size reference) and location details.”

Read the complete LMC Equipment Bulletin 26-001, to learn more. 

References:

NWCG Alerts

LMC Equipment Bulletin 26-001: Aquatic Invasive Species - Seasonal Reminder for Mussels

NWCG Guide to Preventing Aquatic Invasive Species Transport by Wildland Fire Operations, PMS 444

Intermediate Faller (FAL2) Position Task Book Update

Date:  July 24, 2026
Questions? 
Please contact: Tree Felling Subcommittee

NWCG Operations Management Committee (OMC) has issued an update to the NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91. To ensure clarity for both trainees and evaluators, the updated FAL2 Position Task Book (PTB) explicitly states who is authorized to sign off on your tasks:

“Evaluators must be qualified as a FAL2, or an Advanced Faller (FAL1).”

If you are currently working out of a previously published version of the FAL2 PTB, you do not need to restart. However, OMC highly encourages you to take the following step to prevent any confusion in the field:

  • Print and replace the updated evaluator information page (page 2) in your current physical PTB.

References:

Intermediate Faller (FAL2) Position Page

RMC Memo 26-01: Transition Plan for Implementing Updates to Intermediate Faller (FAL2) Position Qualifications

NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Date:  July 10, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics/Equipment Management Committee (LMC) has released Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups. This advisory highlights multiple U.S. Forest Service regions reporting front driveline joint failure incidents.

This advisory recommends firefighters and fire managers to: 

  • Follow all Ram-issued inspection, maintenance, and service guidance for front driveline joints. 
  • Consider installing a driveline loop. 
  • Coordinate with fleet managers and service providers to determine the most appropriate driveline loop kit for each pickup.

For further details, please refer to the complete advisory.

References:

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Technical Service Bulletin: 03-002-21

NEW! NWCG Standard Operating Procedures, PMS 900

Date:  July 9, 2026
Questions? 
Please contact: NWCG Staff

NWCG is excited to announce the publication of the NWCG Standard Operating Procedures, PMS 900.

The new publication establishes general, consistent, and uniform standards for conducting business with the National Wildfire Coordinating Group.

References:

NWCG Standard Operating Procedures, PMS 900