Counter Rotating Vortex Pairs

This module creates both awareness and conversation among fire personnel around a relatively unknown fire behavior phenomenon called the Counter Rotating Vortex Pair (CRVP). Concisely describe conditions that may lead to CRVP formation for tactical resources like crew lookouts and Division Supervisors (DIVS).
Category: Fire-Environment
Core Component(s):
Fire and Aviation Operational Safety, Human Factors, Communication and Decision Making
Estimated Delivery Time: 35 minutes
Video Length: 09:03

 
Image
Screenshot  of Counter Rotating Vortex Pairs Video Tutorial on YouTube
Click on image to open module on YouTube

Intent

Create both awareness and conversation among fire personnel around a relatively unknown fire behavior phenomenon called the Counter Rotating Vortex Pair (CRVP). Concisely describe conditions that may lead to CRVP formation for tactical resources like crew lookouts and Division Supervisors (DIVS).

Facilitator Preparation

  • Review the video and module tools.
  • Consider additional activities and discussion questions pertinent to the location and agency.
  • Familiarize with discussion questions and concepts:
  • Consider what a posted lookout could recognize in terms of weather, topography, fire location, and fire behavior that could lead to CRVP formation.
    • Is the fire located on the lee side of a ridge or mountain range?
      • How would a lookout notice wind shear at ridgetop level?
      • What other terrain features that alter general wind flow can you observe?
        • Ridgetops compress airflow, drainages and canyons funnel airflow.
    • Is there a large column from an area ignition or deep flaming zone?
      • A column impedes wind flow and air must flow around it, which can create vorticity (rock in the river analogy).
      • Is the column splitting into two?
      • Are the columns starting to rotate?
  • Given the information in the video, what are other considerations you may think about specific to lookouts in the future?
    • Examples might be physical location, field of view limitations, and/or time of day.
  • Describe ways resources can work together on a fire to interpret and communicate the fire behavior if the conditions for CRVP formation are present.
    • Examples could be strategically, from the Fire Behavior Analyst (FBAN) to DIVS.
    • Or tactically, between crews and their lookouts on a division.
  • Why are Counter Rotating Vortex Pairs dangerous to fireline personnel?
    • Can create locally strong, unpredicted surface winds that exponentially increase spotting potential on the flanks, where firefighters commonly work.
    • Can result in erratic fire behavior and irregular fire spread patterns.

Facilitating the Discussion

  • Show the video.
  • Facilitate a group discussion using the discussion questions.

Questions / Scenario / Directions

  1. Consider what a posted lookout could recognize in terms of weather, topography, fire location, and fire behavior that could lead to Counter Rotating Vortex Pair formation.
    1. Is the fire located on the lee side of a ridge or mountain range?
      1. How would a lookout notice wind shear at ridgetop level?
      2. What other terrain features that alter general wind flow can you observe?
        1. Ridgetops compress airflow, drainages and canyons funnel airflow.
    2. Is there a large column from an area ignition or deep flaming zone?
      1. A column impedes wind flow and air must flow around it, which can create vorticity (rock in the river analogy from video at 6:27).
      2. Is the column splitting into two or does it appear to be “kidney shaped?”
      3. Are the columns starting to rotate?
  2. Given the information in the video, what are other considerations you may think about specific to lookouts in the future? Examples might be physical location, field of view limitations, and/or time of day.
  3. Describe ways resources can work together on a fire to interpret and communicate the fire behavior if the conditions for CRVP formation are present.
    1. Examples could be strategically, from the FBAN to DIVS.
    2. Or tactically, between crews and their lookouts on a division.
  4. Why are Counter Rotating Vortex Pairs dangerous to fireline personnel?
    1. Can create locally strong, unpredicted surface winds that exponentially increase spotting potential on the flanks, where firefighters commonly work.
    2. Can result in erratic fire behavior and irregular fire spread patterns.

Resources

Additional Video Information

  • This video is also available as a download (zip file, size 1.2GB) with the .srt file for closed captioning (you may need to right click and Save As). For information on how to add closed captioning to a video, see this how to page.
  • Note: For Chrome and Firefox, right click the word download and select Save Link As; for IE, right click and select Save Target As.

Last Modified / Reviewed:

Please Provide Feedback

NWCG values your constructive input and we thank you for taking the time to provide feedback.

Although contact information is optional, we hope that you provide a way for us to contact you in case we need clarification on your comment. If you would like to be contacted regarding your feedback, you must provide contact information. 

Would you like a response?
If you would like a response, you must provide contact information (name and email) below.
One file only.
9.28 GB limit.
Allowed types: gif, jpg, jpeg, png, bmp, eps, tif, pict, psd, txt, rtf, html, odf, pdf, doc, docx, ppt, pptx, xls, xlsx, xml, avi, mov, mp3, mp4, ogg, wav, bz2, dmg, gz, jar, rar, sit, svg, tar, zip.

NWCG Latest Announcements

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1

NWCG NFES Catalog-Part 2: Publications, PMS 449-2

NEW! Air Operations Summary (ICS 220 WF) Now Available

Date: May 2, 2025
Questions?  Please contact:
National Interagency Aviation Committee

The Air Operations Summary (ICS 220 WF) provides the Air Operations Branch with the number, type, location, and specific assignments of helicopters and air resources. The new ICS 220 WF also includes medical extraction capabilities and air resources tracking.

Understanding the capabilities of aviation assets is critical for effective medical and extraction responses. Coordination with the Medical Unit Leader is essential to ensure alignment and consistency between the ICS 220 WF and the Medical Plan (ICS 206 WF). 

References:

Air Operations Summary (ICS 220 WF)

National Interagency Aviation Committee

Incident Command System (ICS) Forms