Airtankers

Airtanker Typing Standard

TYPE CAPACITY GALLONS EXAMPLES
VLAT >6000 DC-10
1 3,000 – 5,999 BAe-146, RJ85, MD-87, C-130, B-737
2 1,800 – 2,999 Q-400, CV-580, P-3
3 800 to 1,799 S-2T, AT-802F
4 Up to 799 Thrush, M18T

Note: Tanker capacity standards may vary by agency.

Airtanker Resources


Helicopters

Helicopter Typing Standard

Components Type 1 Type 2 Type 3
Allowable payload at 59° F at sea level 5,000 2,500 1,200
Passenger seats 15 or more 9 - 14 4 - 8
Retardant or water-carrying capability (gal) 700 300 100
Maximum gross takeoff and landing weight (lb) 12,501+ 6,000 - 12,500 Up to 6,000
Examples CH-54 / CH-47 Bell 204, 205 A1++, 212 HP Bell 407, A-Star B3
Helitanker
  • Fixed tank
  • 1,100 minimum gallon capacity

Helicopter Resources


Unmanned Aircraft Systems (UAS)

UAS Typing Standard

Type Configuration Endurance Data Collection Altitude (agl) Max Range (miles) Typical Sensors*
1 Fixed-Wing
Rotocraft
6-14 hrs.
N/A
3,500-8,000
N/A
50
N/A
EO/Mid Wave IR
High Quality IR
2 Fixed-Wing
​Rotocraft
1-6 hrs.
N/A
3,500-6,000
​N/A
25
N/A
EO/Long Wave IR
​Moderate Quality IR
3 Fixed-Wing
​Rotocraft
20-60 min.
20-60 min.
2,500 and Below
2,00 and Below
5
5
EO/IR Video and Stills
​Moderate Quality IR
4 Fixed-Wing
​Rotocraft
Up to 30 min.
Up to 20 min.
1,200 and Below
1,200 and Below
<2
<2
EO/IR Video and Stills
​Moderate Quality IR

*Sensor payloads are variable but typically include daylight (electro-optical), infrared (IR), thermal, or mapping cameras. Type 1 and 2 UAS carry multiple camera types in a gimbaled configuration.

Note: Certain aircraft are specialized and will not fit this classification.

Additional current information can be accessed on the Interagency Fire UAS Operations website.

UAS Resources

NWCG Latest Announcements

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1

NWCG NFES Catalog-Part 2: Publications, PMS 449-2