Airtankers

Airtanker Typing Standard

TYPE CAPACITY GALLONS EXAMPLES
VLAT >6000 DC-10
1 3,000 – 5,999 BAe-146, RJ85, MD-87, C-130, B-737
2 1,800 – 2,999 Q-400, CV-580, P-3
3 800 to 1,799 S-2T, AT-802F
4 Up to 799 Thrush, M18T

Note: Tanker capacity standards may vary by agency.

Airtanker Resources


Helicopters

Helicopter Typing Standard

Components Type 1 Type 2 Type 3
Allowable payload at 59° F at sea level 5,000 2,500 1,200
Passenger seats 15 or more 9 - 14 4 - 8
Retardant or water-carrying capability (gal) 700 300 100
Maximum gross takeoff and landing weight (lb) 12,501+ 6,000 - 12,500 Up to 6,000
Examples CH-54 / CH-47 Bell 204, 205 A1++, 212 HP Bell 407, A-Star B3
Helitanker
  • Fixed tank
  • 1,100 minimum gallon capacity

Helicopter Resources


Unmanned Aircraft Systems (UAS)

UAS Typing Standard

Type Configuration Endurance Data Collection Altitude (agl) Max Range (miles) Typical Sensors*
1 Fixed-Wing
Rotocraft
6-14 hrs.
N/A
3,500-8,000
N/A
50
N/A
EO/Mid Wave IR
High Quality IR
2 Fixed-Wing
​Rotocraft
1-6 hrs.
N/A
3,500-6,000
​N/A
25
N/A
EO/Long Wave IR
​Moderate Quality IR
3 Fixed-Wing
​Rotocraft
20-60 min.
20-60 min.
2,500 and Below
2,00 and Below
5
5
EO/IR Video and Stills
​Moderate Quality IR
4 Fixed-Wing
​Rotocraft
Up to 30 min.
Up to 20 min.
1,200 and Below
1,200 and Below
<2
<2
EO/IR Video and Stills
​Moderate Quality IR

*Sensor payloads are variable but typically include daylight (electro-optical), infrared (IR), thermal, or mapping cameras. Type 1 and 2 UAS carry multiple camera types in a gimbaled configuration.

Note: Certain aircraft are specialized and will not fit this classification.

Additional current information can be accessed on the Interagency Fire UAS Operations website.

UAS Resources

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505