Hand Crews

Minimum Crew Standards for National Mobilization

Minimum Standards Type 1 IHC (Interagency Hotshot Crew) Type 2 with IA (Initial Attack) Capability Type 2
Fireline Capability Initial attack/can be broken up into squads, fireline construction, complex firing operations (backfire). Initial attack/can be broken up into squads, fireline construction, firing to include burnout. Initial attack, fireline construction, firing as directed.
Crew Size 18 - 22 18 - 20
Leadership Qualifications Permanent supervision:
Supt.: TFLD, ICT4, FIRB
Asst. Supt.: STCR or TFLD and CRWB and ICT4
3 Squad Leaders: CRWB and ICT5
2 Senior Firefighters: FFT1
Crew Boss: CRWB
3 Squad Bosses: ICT5
Crew Boss: CRWB
3 Squad Bosses: FFT1
Language Requirement All senior leadership, including Squad Leaders and higher must be able to read and interpret the language of the crew as well as English.
Experience 80% 1 season 60% 1 season 20% 1 season
Full-Time Organized Crew Yes (work and train as a unit 40 hours per week. No No
Communications 8 programmable radios 4 programmable radios
Sawyers 4 certified as FAL2 and 50% of crew certified as FAL3 or better. 3 agency-qualified None
Training As required by the Standards for Interagency Hotshot Crew Operations or agency policy prior to assignment Basic firefighter training and/or annual fireline safety refresher prior to assignment Basic firefighter training and/or annual fireline safety refresher prior to assignment
Logistics Crew level agency purchasing authority No purchasing authority No purchasing authority
Maximum Weight 5,300 lb
Dispatch Availability Available nationally Available nationally Variable
Production Factor 1.0 .8 .8
Transportation Own transportation Transportation needed Transportation needed
Tools & Equipment Fully equipped Not equipped Not equipped
Personal Gear Arrives with: Crew first aid kit, personal first aid kit, headlamp, 1-qt canteen, web gear, sleeping bag
Personal Protective Equipment (PPE) All standard designated fireline PPE
Certification Must be annually certified by the local host unit agency administrator or designee prior to being made available for assignment. N/A N/A

N/A = Not applicable

Crew Resources

NWCG Latest Announcements

WFSTAR 2025 Core Component Module Package and 2024 Fire Year in Review Now Available

Date: March 14, 2025
Questions?  Please contact:
Joe Schindel at mschindel@blm.gov
 

The 2025 Core Component Module Package for RT-130, Wildland Fire Safety Training Annual Refresher (WFSTAR) and the 2024 Fire Year in Review are now available on the NWCG website. The 2025 Core Component Module Package provides all content needed to deliver RT-130.

References:

2025 Core Component Module Package

2024 Fire Year in Review Module

NEW! NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053

Date: March 12, 2025
Contact: Wildland Urban Interface Mitigation Committee

The NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 provides mitigation practitioners at all experience levels with recommendations on the most effective and efficient ways to accomplish mitigation work in communities at risk to wildfire damage or destruction. The content in this guide was written in coordination with the NWCG Standards for Mitigation in the Wildland Urban Interface, PMS 052.

References:

NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 

Updated, NWCG Standards for Wildland Fire Module Operations, PMS 430

Date: March 11, 2025
Contact: Fire Use Subcommittee
Wildland Fire Module Unit

The NWCG Standards for Wildland Fire Module Operations, PMS 430 standardizes procedures and expectations for Wildland Fire Modules (WFMs). These standards are to be used by staff, supervisors, specialists, and technicians for planning, administering, and conducting WFM operations. These standards will also be used as a measure of WFM qualifications, capabilities, and expected performance, for both Type 1 and Type 2 WFMs.

References:

NWCG Standards for Wildland Fire Module Operations, PMS 430

NEW! NWCG Standards for Airtanker Operations, PMS 514

Date: March 7, 2025
Contact: National Interagency Aviation Committee

The NWCG Standards for Airtanker Operations, PMS 514 establishes the standards for dispatching, utilizing, and coordinating airtankers on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, NWCG Standards for Airtanker Base Operations (SABO), PMS 508, and any applicable agency plans.

References:

NWCG Standards for Airtanker Operations, PMS 514