The characteristics of an effective deployment site have not changed. Your goal in selecting a deployment site is to keep the fire shelter away from heat, especially flames. Practice evaluating deployment sites so that you can recognize them quickly under stress. Identify effective sites whenever you are on the fireline so you know where they are before you need one.

A rocky mountain forest

1. Keep away from narrow draws, chutes, and chimneys. They tend to funnel smoke, flames, and hot gases that can damage your shelter.

A rocky mountain forest

2. Avoid saddles on ridgetops. They also funnel smoke and heat.


A dirt road in through wildland forest.

3. Flat areas on slopes, such as benches, or road cuts, offer some protection from radiant and convective heat. These level areas can keep you below the path of flame and convective heat. Do not deploy in the middle of a road if vehicles may be passing. A drainage ditch on the uphill side of a road cut can be an effective deployment site unless it contains fuels that could ignite and burn the shelter. Four firefighters deployed their fire shelters on this road during a burnover. All four survived with only minor burns.

A rocky mountain forest

4. Stay out of draws, even when deploying on a road.


Birds eye view of a smoke rising above trees in a forest
A rockslide with tall trees in the forefront
A rocky mountain forest.
5. Try to pick natural firebreaks such as wet meadows, wide streambeds, swampy areas, and rockslides.


A rocky mountain forest
A rocky mountain forest
6. Do not deploy in or next to tall or thick grass, small trees, trees with low branches, brush, piles of slash, or firefighting equipment such as packs, parachutes, tools, or chain saws. Firefighters have been burned because they deployed too close to such fuels. Large rockslides can be effective deployment sites, but you must stay away from brush and trees, and from fuels scattered in the rocks. Even though it can be difficult to hold the edges of the shelter down, large, jumbled rocks, rockslides sometimes offer the largest area free of fuels and may be the best option for deployment.


A rocky mountain forest

7. Ground fuels, such as grass, or tree litter, can ignite rapidly. Clear the deployment site to mineral soil if time allows. If time is critical, pick a site with the sparsest fuels.

A rocky mountain forest

8. Deploy fire shelters well away from thick vegetation such as the shrubby understory and trees.


A rocky mountain forest

9. Boulders, large rocks, buildings, vehicles, and equipment can provide buffers from the heat of the fire. Keep in mind that when vehicles, equipment, and buildings catch fire, they burn hot, and for a much longer duration than the vegetation around them. This can lead to shelters being exposed to heat for a prolonged period, well after the flame front has passed. This may keep firefighters in their shelters longer, exposed to prolonged levels of dangerous heat.

A rocky mountain forest

10. Avoid areas where rocks or logs can roll on you or snags can fall on you.


A rocky mountain forest

11. The lee side of a ridgetop can be an effective deployment site because the flames and hot gases tend to rise above the ridge. Fire intensity usually drops when fire reaches a ridge. But be alert for the possibility that firebrands might ignite fires below you on the lee side of the ridge.

A rocky mountain forest

12. Burned-out areas can be effective deployment sites if there is no fuel left to reburn. Be aware of residual heat and hotspots on the ground. Scrape the ground if possible to clear away any heat and burning materials. Burn injuries have occurred from firefighters deploying in the black that was still hot.


A rocky mountain forest
A rocky mountain forest
13. Wide areas that have been cleared of fuel, such as dozer lines or roads, can be good deployment sites, depending on the size of the area that has been cleared and the behavior of the fire.

 

A rocky mountain forest
A rocky mountain forest
14. Bodies of water can be adequate deployment zones, however you should be aware of several hazards if you find yourself having to use a body of water. Deployments can last from several minutes to an hour or more. If the water is over your head in depth, you may be at higher risk of drowning especially once your boots and clothing become waterlogged. Since water removes heat from the body much faster than air, you may be at risk of hypothermia from deployments in bodies of water. If there is a current to the water your fire shelter may be hard to hold on to or you may become entangled in your shelter and drown. The fire shelter’s ends can fill with water and become very heavy. For further information read this tech tip on deploying in bodies of water.

 

 

NWCG Latest Announcements

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1

NWCG NFES Catalog-Part 2: Publications, PMS 449-2