Skip to main content

Surface Fire Behavior Nomograms and Nomographs

  1. Instructions for Nomograph Use (Scott 2007)
  2. Instructions for Nomogram Use (Rothermel 1983)

Instructions for Nomograph Use (Scott 2007)

Reference: Scott, Joe H. 2007. Nomographs for estimating surface fire behavior characteristics. Gen. Tech. Rep. RMRS-GTR-192. Fort Collins, CO: U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station. 119 p

Each fuel model includes a duplicate set of effective windspeed protractor and fire behavior nomograph, one for low windspeeds and one for high windspeeds. Select the one with applicable windspeeds.

Example Nomograph

Image
Example Nomograph. Updated in 2007 to include versions for all 53 models.

Inputs Required:

  1. Fuel Model.
  2. Midflame Windspeed and direction, azimuth clockwise from upslope.
  3. Slope percent.
  4. Dead and Live Fuel Moistures.

Determine Effective Windspeed (EWS) - Low or High

Use the left side nomograph, shown above, if the situation includes cross slope winds.

  1. Plot the slope vector (a) in the upslope direction to the hash representing the slope percent. Interpolate if necessary.
  2. Plot the wind vector (b) using the concentric circle to for the input windspeed and the azimuth above for direction.
  3. Plot parallel vectors (c and d) and resultant vector (e). Read resulting windspeed (e) and direction (f).

Estimate Head Fire Rate of Spread and Flame Length

If the fuel model includes a live fuel component, use the nomograph that references the appropriate live fuel moisture. Otherwise, there is only one nomograph, shown on right.

  1. Using the input dead fuel moisture, draw vertical line (g) to the estimated EWS curve.
  2. Read the flame length from the embedded curves at the intersection (j). Interpolate between lines if necessary.
  3. Draw horizontal line (h) to the left axis and read the Rate of Spread at intersection (i).

Return to Top

Instructions for Nomogram Use (Rothermel 1983)

Reference: Rothermel, Richard C. How to predict the spread and intensity of forest and range fires. Gen. Tech. Rep. INT-143. Ogden, UT: U.S. Department of Agriculture, Forest Service, Intermountain Forest, and Range Experiment Station; 1983. 1 61 p. 

Download Nomograms Here 

Return to Top

Unlike the newer nomographs, the original surface fire behavior nomograms have several limitations:

  • These nomograms are only available for the original 13 fuel models.
  • They are intended for use with wind blowing within ±30 degrees of upslope. Use in vectoring is possible, though it is not outlined here.

Inputs Required

  1. Fuel model.
  2. Midflame windspeed.
  3. Percent slope.
  4. Dead fuel moisture (use 1-hr).
  5. Live fuel moisture for fuel models 2, 4, 5, 7, & 10.

Select the Appropriate Windspeed (Low/High) Nomogram

The numbered steps below correspond to the labeled lines on the example nomograms.

Part I: Estimate Effective Windspeed (For All Fuel Models)

  1. In the lower left quadrant, draw a vertical line from percent slope value to intersect midflame windspeed curve. Draw a horizontal line to the left axis and read effective windspeed.
  2. In the lower right quadrant, identify and highlight the appropriate effective windspeed line. Interpolate by adding a line for effective windspeed from step1 above if it is between existing lines.

Return to Top

Part II: Fuel Moisture

For FM 1, 3, 6, 8, 9, 11, 12, 13 with only dead fuel.

  1. In the upper left quadrant of the nomogram, identify and highlight the appropriate dead fuel moisture line based on the input value provided. Interpolate by drawing a new line between existing lines if necessary.

For FM 2, 4, 5, 7, 10 with live fuel.

  • Using the two upper quadrants, locate the appropriate dead fuel moisture value on the two outer vertical axes (highlighted). Connect with a horizontal line.
  • Connect the point where the horizontal line intersects the live fuel curve in the upper left quadrant to the origin point, creating a straight line.
  • Using the input live fuel moisture provided, identify and highlight the appropriate S-curve in the upper right quadrant. Interpolate by adding a new line between existing lines if necessary.

At this point, turning lines have been identified in all 4 quadrants (including the S-curve in the upper right quadrant and the default corner to corner line in the lower left). The nomogram is prepared for Part III.

Part III: Estimating Fire Behavior

With the preparations in parts I and II, turning lines have been highlighted in the lower right quadrant and the upper left quadrant, as well as the appropriate S-curve in the upper right quadrant for fuel models with live fuels.

  • Begin in the upper right quadrant. Draw a horizontal line from dead fuel moisture to the highlighted fuel moisture turning line (s-curve).
  • From the intersection, draw a vertical line down to the turning line in the lower right quadrant (highlighted in step 2).
  1. From the intersection with the turning line in the lower right, draw a horizontal line to the turning line in the lower left quadrant.
  2. From the intersection with the turning line in the lower left quadrant, draw a vertical line up to the turning line in the upper left quadrant (highlighted in step 3).
  3. From the intersection with the turning line in the upper left quadrant, draw a horizontal line to the right until it intersects the vertical line drawn in step 4.

Part IV: Reading Fire Behavior Outputs

Read Heat Per Unit Area where the vertical line from step 2 intersects its axis in the upper right quadrant.

  • In the first example (Dead Fuel Only), the Heat Per Unit Area is estimated at approximately 750 BTU/sq. ft.
  • In the second example (Dead & Live Fuels), the Heat Per Unit Area is estimated at approximately 215 BTU/sq. ft.

Read Rate of Spread where the horizontal line from step 5 intersects its axis in the upper right quadrant.

  • In the first example (Dead Fuel Only), the Rate of Spread is estimated at approximately 7 chains per hour.
  • In the second example (Dead & Live Fuels), the Rate of Spread is also estimated at approximately 7 chains per hour.

Read Flame Length and Fireline Intensity at the final intersection produced in step 5.

  • In the first example (Dead Fuel Only), the intersection between lines 4 and 7 comes between the Flame Length/Fireline Intensity contour lines 3/60 and 4/100. It could be estimated as 4 ft or 90 BTU/ft/sec.
  • In the second example (Dead & Live Fuels), the intersection between lines 4 and 7 comes between the Flame Length/Fireline Intensity contour lines 2/25 and 3/60. It could be estimated as 2 ft or 30 BTU/ft/sec.

Example Nomogram for Dead Fuel Only (Fuel Models 1, 3, 6, 8, 9, 11, 12, 13)

Image
Example Surface Fire Behavior Nomogram for fuel models with dead fuels only.

Example Nomogram Using Dead & Live Fuels (Fuel Models 2, 4, 5, 7, 100)

Image
Example Surface Fire Behavior Nomogram for fuel models with both live and dead fuels.

Return to Top

NWCG Latest Announcements

National Wildland Firefighter Day

Date: July 2, 2025
Questions?  Please contact:
National Interagency Fire Center

The National Wildfire Coordinating Group (NWCG) recognizes July 2, 2025, as National Wildland Firefighter Day (NWFFD). Established in 2022, NWFFD honors the dedication of wildland firefighters and support personnel. This day falls within the 2025 Week of Remembrance (June 30 - July 6), providing an opportunity to renew our commitment to wildland firefighter safety while remembering those who have fallen in the line of duty.

NWCG provides leadership to enable interoperable wildland fire operations among federal, state, local, Tribal, and territorial partners. NWCG standards and training establish common practices to contribute to safe, effective, and coordinated interagency wildland fire operations nationwide.

References:

Week of Remembrance

National Wildland Firefighter Day

2025 Week of Remembrance

Date: June 27, 2025
Questions?  Please contact:
6 Minutes for Safety Subcommittee

As we approach the 2025 Week of Remembrance (WOR), June 30–July 6, we dedicate this time to reflect on the past incidents from 2015 and honor the fallen through learning. Since its inception in 2014, WOR has honored wildland firefighters who made the ultimate sacrifice while encouraging critical discussions that reinforce lessons learned.

Throughout the week, we encourage thoughtful and generative conversations—whether in briefing rooms or at tailgates—that promote a culture of continuous learning and safety.

References:

2025 Week of Remembrance: Letter to Leadership

Wildland Fire Lessons Learned Center

ETC Equipment Bulletin: 25-003 Flame-Resistant Shirt Survey

Date: June 12, 2025
Questions?  Please contact:
Equipment Technology Committee

The U.S. Forest Service National Technology and Development Program (NTDP) is seeking input on the Forest Service-designed flame-resistant (FR) shirt, currently available through the National Interagency Support Cache system and FedMall.

NTDP is conducting a product review to improve future FR shirt designs. As part of this effort, a short survey is now open for federal employees who have worn any of three recent FR shirt models. Feedback will guide design improvements to better meet the needs of wildland firefighters.

To comply with the Paperwork Reduction Act, responses are limited to federal employees. The survey is open through September 12, 2025. 

References:

NWCG Alerts

ETC Equipment Bulletin: 25-003

NEW! S-130, Firefighter Training (Blended) Now Available

Date: June 10, 2025
If you have questions, please visit our FAQ page. 
If your question is not answered there, you can 
submit your question using our Contact Us form. 
 

The S-130, Firefighter Training (Blended), equips new wildland firefighters with essential skills through a mix of online learning and hands-on training. The course features a required online component and an instructor-led exercise, reinforcing online concepts with practical performance-based training.

The course builds competencies in wildland fire operations, safety, and equipment use, applicable across various operational environments. Both the online component and instructor-led field exercise must be completed to receive a certificate of completion. Students are required to finish the prerequisite S-190, Introduction to Wildland Fire Behavior, before enrolling in S-130, Firefighter Training (Blended).

References:

S-130, Firefighter Training (Blended)

S-190, Introduction to Wildland Fire Behavior

Wildland Fire Learning Portal