Skip to main content

5.4 Perimeter and Area Estimation Charts

The perimeter and area of a fire can be determined by using estimation charts as shown below. These charts require knowledge of the spread distance in chains and the effective windspeed in miles per hour. A fire area/size worksheet is provided to be filled out with the data collected.

EFFECTIVE WINDSPEED

Effective windspeed is the midflame windspeed, corrected for the effects of slope on fire spread. Changes in slope affect how wind influences a fire and the overall fire spread. For slopes above 20%, each additional 20% increase in slope translates to an additional 1 mph increase in the effective equivalent “upslope” component of the wind. For slopes between 20% and 40%, for example, a 1-mph slope-equivalent upslope component would be added to the flame-level wind. Between 40% and 60%, a 2-mph slope-equivalent upslope component would be added, and above 60%, flame-level winds would increase by 3 mph.
 

screengrab of animation of flame heights increasing as slope increases
Click to view animation of slope effects on fire

Example 1 - A fire starts at point A. Given the following values, determine the fire perimeter. 
rate of spread = 5 ch/h, projection time = 3 h, effective windspeed = 10 mi/h

Step 1. Use the equation for determining the spread distance (see Section 5.3).
ROS × PT = 5 ch/h × 3 h = 15 chains spread distance.

Step 2.> Look at the perimeter estimation chart. Find a spread distance of 15 chains on the vertical axis. Move your gaze across horizontally.

Step 3. Find an effective windspeed of 10 miles/hour on the horizontal axis, which is between 9 miles/hour and 11 miles/hour. Follow the column down vertically.

Step 4. Where the two lines intersect, read the number. In this case there are two numbers.
34 chains and 33 chains

Step 5. Take an average of the two values.
34.0 chains + 33.0 chains / 2 = 33.5 chains

The perimeter of the fire is 33.5 chains.

Example 2 - Determine the area of the fire in Example 1 and complete the fire area/size worksheet. The spread distance is the same, 15 chains.

Step 1. Reference the area estimation chart for a spread distance of 15 chains. Follow the row across horizontally.

Step 2. Look for an effective windspeed of 10 miles/hour, which is between 9 miles/hour and 11 miles/hour. Follow the column down vertically and read the numbers from the two windspeeds.
4.9 acres and 5.7 acres

Step 3. Take an average of the two values.
4.9 acres + 5.7 acres / 2 = 5.3 acres

The area of the fire is 5.3 acres.

Perimeter estimation for point source fires.
Table showing Perimeter Estimation

Area estimation for point source fires.
point source fires

Fire Area/Size Worksheet

Line Input    
0 PP Projection point A
1 ROS Rate of spread, ch/h 5
2 EWS Effective windspeed, mi/h 10
3 PT Projection time, h 3
4 SDF Spread distance, ch 15
  Output    
  PER Perimeter, ch 33.5
  AC Area, ac 5.3

NWCG Latest Announcements

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: April 23, 2025
Questions?  Please contact:
Interagency Fire Unmanned Aircraft Systems Subcommittee

The NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 standardizes processes and procedures for the interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This updated publication provides the aviation community with standards to ensure UAS are used safely, effectively, and efficiently in support of fire management goals and objectives.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

NWCG National Interagency Aviation Committee

ETC Bulletin 25-001: Retrofitted Hot/Cold Beverage Kits - 2025 Field Season

Date: April 16, 2025
Questions?  Please contact:
Equipment Technology Committee

Due to spout failures and the associated risk of burn injuries, manufacturers have retrofitted the Hot/Cold Beverage Kits using a heat-shrinking band to secure the black spout at the insertion site. The updated kits feature a fluorescent label on each full kit assembly for easy identification. Catering units are encouraged to confirm the clear heat-shrinking bands are intact around each spout before filling.

ETC Bulletin 24-001 regarding Hot/Cold Beverage Kits has been archived and replaced by ETC Bulletin 25-001 for the 2025 season.

References:

NWCG Alerts

ETC-EB-25-001 Retrofitted Hot/Cold Beverage Kits

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog