Skip to main content

5.4 Perimeter and Area Estimation Charts

The perimeter and area of a fire can be determined by using estimation charts as shown below. These charts require knowledge of the spread distance in chains and the effective windspeed in miles per hour. A fire area/size worksheet is provided to be filled out with the data collected.

EFFECTIVE WINDSPEED

Effective windspeed is the midflame windspeed, corrected for the effects of slope on fire spread. Changes in slope affect how wind influences a fire and the overall fire spread. For slopes above 20%, each additional 20% increase in slope translates to an additional 1 mph increase in the effective equivalent “upslope” component of the wind. For slopes between 20% and 40%, for example, a 1-mph slope-equivalent upslope component would be added to the flame-level wind. Between 40% and 60%, a 2-mph slope-equivalent upslope component would be added, and above 60%, flame-level winds would increase by 3 mph.
 

screengrab of animation of flame heights increasing as slope increases
Click to view animation of slope effects on fire

Example 1 - A fire starts at point A. Given the following values, determine the fire perimeter. 
rate of spread = 5 ch/h, projection time = 3 h, effective windspeed = 10 mi/h

Step 1. Use the equation for determining the spread distance (see Section 5.3).
ROS × PT = 5 ch/h × 3 h = 15 chains spread distance.

Step 2.> Look at the perimeter estimation chart. Find a spread distance of 15 chains on the vertical axis. Move your gaze across horizontally.

Step 3. Find an effective windspeed of 10 miles/hour on the horizontal axis, which is between 9 miles/hour and 11 miles/hour. Follow the column down vertically.

Step 4. Where the two lines intersect, read the number. In this case there are two numbers.
34 chains and 33 chains

Step 5. Take an average of the two values.
34.0 chains + 33.0 chains / 2 = 33.5 chains

The perimeter of the fire is 33.5 chains.

Example 2 - Determine the area of the fire in Example 1 and complete the fire area/size worksheet. The spread distance is the same, 15 chains.

Step 1. Reference the area estimation chart for a spread distance of 15 chains. Follow the row across horizontally.

Step 2. Look for an effective windspeed of 10 miles/hour, which is between 9 miles/hour and 11 miles/hour. Follow the column down vertically and read the numbers from the two windspeeds.
4.9 acres and 5.7 acres

Step 3. Take an average of the two values.
4.9 acres + 5.7 acres / 2 = 5.3 acres

The area of the fire is 5.3 acres.

Perimeter estimation for point source fires.
Table showing Perimeter Estimation

Area estimation for point source fires.
point source fires

Fire Area/Size Worksheet

Line Input    
0 PP Projection point A
1 ROS Rate of spread, ch/h 5
2 EWS Effective windspeed, mi/h 10
3 PT Projection time, h 3
4 SDF Spread distance, ch 15
  Output    
  PER Perimeter, ch 33.5
  AC Area, ac 5.3

NWCG Latest Announcements

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1

NWCG NFES Catalog-Part 2: Publications, PMS 449-2